scx200_hrt.c 2.54 KB
Newer Older
1
// SPDX-License-Identifier: GPL-2.0-or-later
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41
/*
 * Copyright (C) 2006 Jim Cromie
 *
 * This is a clocksource driver for the Geode SCx200's 1 or 27 MHz
 * high-resolution timer.  The Geode SC-1100 (at least) has a buggy
 * time stamp counter (TSC), which loses time unless 'idle=poll' is
 * given as a boot-arg. In its absence, the Generic Timekeeping code
 * will detect and de-rate the bad TSC, allowing this timer to take
 * over timekeeping duties.
 *
 * Based on work by John Stultz, and Ted Phelps (in a 2.6.12-rc6 patch)
 */

#include <linux/clocksource.h>
#include <linux/init.h>
#include <linux/module.h>
#include <linux/ioport.h>
#include <linux/scx200.h>

#define NAME "scx200_hrt"

static int mhz27;
module_param(mhz27, int, 0);	/* load time only */
MODULE_PARM_DESC(mhz27, "count at 27.0 MHz (default is 1.0 MHz)");

static int ppm;
module_param(ppm, int, 0);	/* load time only */
MODULE_PARM_DESC(ppm, "+-adjust to actual XO freq (ppm)");

/* HiRes Timer configuration register address */
#define SCx200_TMCNFG_OFFSET (SCx200_TIMER_OFFSET + 5)

/* and config settings */
#define HR_TMEN (1 << 0)	/* timer interrupt enable */
#define HR_TMCLKSEL (1 << 1)	/* 1|0 counts at 27|1 MHz */
#define HR_TM27MPD (1 << 2)	/* 1 turns off input clock (power-down) */

/* The base timer frequency, * 27 if selected */
#define HRT_FREQ   1000000

42
static u64 read_hrt(struct clocksource *cs)
43 44
{
	/* Read the timer value */
45
	return (u64) inl(scx200_cb_base + SCx200_TIMER_OFFSET);
46 47 48 49 50 51 52
}

static struct clocksource cs_hrt = {
	.name		= "scx200_hrt",
	.rating		= 250,
	.read		= read_hrt,
	.mask		= CLOCKSOURCE_MASK(32),
53
	.flags		= CLOCK_SOURCE_IS_CONTINUOUS,
54 55 56 57 58
	/* mult, shift are set based on mhz27 flag */
};

static int __init init_hrt_clocksource(void)
{
59
	u32 freq;
60
	/* Make sure scx200 has initialized the configuration block */
61 62 63 64 65 66 67
	if (!scx200_cb_present())
		return -ENODEV;

	/* Reserve the timer's ISA io-region for ourselves */
	if (!request_region(scx200_cb_base + SCx200_TIMER_OFFSET,
			    SCx200_TIMER_SIZE,
			    "NatSemi SCx200 High-Resolution Timer")) {
68
		pr_warn("unable to lock timer region\n");
69 70 71 72
		return -ENODEV;
	}

	/* write timer config */
73
	outb(HR_TMEN | (mhz27 ? HR_TMCLKSEL : 0),
74 75
	     scx200_cb_base + SCx200_TMCNFG_OFFSET);

76 77 78 79
	freq = (HRT_FREQ + ppm);
	if (mhz27)
		freq *= 27;

80
	pr_info("enabling scx200 high-res timer (%s MHz +%d ppm)\n", mhz27 ? "27":"1", ppm);
81

82
	return clocksource_register_hz(&cs_hrt, freq);
83 84 85 86 87 88 89
}

module_init(init_hrt_clocksource);

MODULE_AUTHOR("Jim Cromie <jim.cromie@gmail.com>");
MODULE_DESCRIPTION("clocksource on SCx200 HiRes Timer");
MODULE_LICENSE("GPL");