dts: imx8mq-librem5: Set bq25895 thermal regulation threshold to 60°C
Compare changes
Due to an influx of spam, we have had to impose restrictions on new accounts. Please see this page for instructions on how to get full permissions. Sorry for the inconvenience.
source.puri.sm will be down starting March 18, 6:00 UTC, for a server migration. We expect the migration to take up to 4 hours.
The default value is 120°C, meaning that bq25895 won't start limiting charging current until its internal temperature reaches that level. 120°C seems a bit high for a handheld device, so let's reduce this value to 60°C.