  • Shawn Guo's avatar
    mx51evk: Fix 2 hours reset issue · 888b4f43
    Shawn Guo authored
    
    
    The mx51evk u-boot has an issue that system will get reset
    every 2 hours.
    
    MC13892 has an inside charge timer which expires in 120 minutes.
    If ICHRG and CHGAUTOB are not set properly, this timer expiration
    will get system power recycled.
    
    Since mx51evk has no Li-Ion battery on board, the patch sets
    ICHRG in externally powered mode and sets CHGAUTOB bit to avoid
    automatic charging, so that system will not get reset by this
    timer expiration.
    
    The patch also corrects the bit field definition of register 48
    (Charger 0) per latest MC13892 Reference Manual.
    
    Signed-off-by: default avatarShawn Guo <shawn.gsc@gmail.com>
    888b4f43