Skip to content
  • Chen Hu's avatar
    serial: 8250_dw: always set baud rate in dw8250_set_termios · 1964062d
    Chen Hu authored
    commit dfcab6ba
    
     upstream.
    
    dw8250_set_termios() doesn't set baud rate if the arg "old ktermios" is
    NULL. This happens during resume.
    Call Trace:
    ...
    [   54.928108] dw8250_set_termios+0x162/0x170
    [   54.928114] serial8250_set_termios+0x17/0x20
    [   54.928117] uart_change_speed+0x64/0x160
    [   54.928119] uart_resume_port
    ...
    
    So the baud rate is not restored after S3 and breaks the apps who use
    UART, for example, console and bluetooth etc.
    
    We address this issue by setting the baud rate irrespective of arg
    "old", just like the drivers for other 8250 IPs. This is tested with
    Intel Broxton platform.
    
    Signed-off-by: default avatarChen Hu <hu1.chen@intel.com>
    Fixes: 4e26b134
    
     ("serial: 8250_dw: clock rate handling for all ACPI platforms")
    Cc: Heikki Krogerus <heikki.krogerus@linux.intel.com>
    Cc: stable <stable@vger.kernel.org>
    Reviewed-by: default avatarAndy Shevchenko <andriy.shevchenko@linux.intel.com>
    Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
    1964062d