Version 0.2.0
- 0x06: Bump customer use word
- 0x28:
- Port information: Drop try.Src - not needed and cofuses DR use
- Type-C Current: Use weakest pullup - we only want to provide 500mA without a PD contract.
- Over Voltage Protection Usage: Disconnect at trip point
- Try.Src: Disable - wo have no interest in charging a laptop
- Process Swap To Source: disable, we're a source initially
- Process VCONN Swap: Disable, we're a VConn source initially and don't want to sink VConn
- Initiate VCONN Swap: disable, we're a source initially if required.
- Automatic Sink Capabilities Request: Disable, sink will make itself clear if necessary.
- 0x33:
- Limit number of sink PDOs to 1 (leaving 5V/3A)
- Use 0.5/1/3A min/normal/max operating current
- 0x37:
- Autonegotiate Variable Sink Enable: disable, just support fixed sinks for now
- Autonegotiate Battery Sink Enable: disable, just support fixed sinks for now
- Offer priority: Choose highest current
- Automatically Calculate Min Power Required: Disable
- Minimum Power Required: 5W, that's enough as a start